Structure & Envelope · Air sealing

Sealed tight, then tested

Most of the heat a house loses in winter slips out through gaps you never see: where walls meet the floor and roof, and around every wire, pipe, and window. We seal those gaps ourselves, then a fan test called a blower door measures how tight the house really is.

This isn't a choice you need to make. It's how every Bedrock home is built.

Blower door test fan set in a front doorPhoto: Andy Harper

Every Bedrock home

How we build it

Two steps on every home: we seal every gap ourselves, then an outside tester proves it.

1234561 Where walls meet the foundation2 Around windows and doors3 Outlets, wires, and pipes4 Top of the walls5 Lights and fans in the ceiling6 Vents and flues through the roofThe air barrier

We seal every gap ourselves

Before any insulation goes in, we go through the whole house ourselves and seal every gap: where the walls meet the foundation and the roof, around every window and door, and every hole drilled for wires, pipes, and vents. We don't leave it to a sub, so it gets done right.

Fewer drafts and cold spots

Lower heating bills

Less moisture and dust moving into the walls

Every home is tested

When your home is finished, an outside tester runs a blower door test: a fan in an exterior door pulls air out of the house and measures how much leaks back in. Every home has to pass Washington's energy code limit, and you get the result with your closeout documents.

Proof of how tight your home really is

A number you can compare to code

Required to pass final inspection

Set by your envelope package

How tight, and how it's tested

Every home is sealed by hand. Higher packages add sealed layers built in while the house is framed, aim for a tighter result, and on Better and Best, test twice.

Good package

Sealed by hand, tested at the end

We seal every gap by hand with foam and caulk and tape the seams of the outside foam board. One final blower door test confirms the house meets the energy code limit.

TargetCode limit: 5 air changes per hourTestedOnce, when the house is finished

Better package

An air barrier built in from framing day, tested twice

The sheathing itself becomes a taped air barrier, and tape over the top plates ties it to a sealed membrane on the ceiling as the walls go up. We test before drywall to catch leaks while they're easy to fix, and again at the end, to well under half of what code allows.

Target2 air changes per hour or lessTestedTwice: before drywall and when finished

Best package

Sealed from framing to finish, tested twice

A fully adhered membrane wraps the outside and a second sealed membrane lines the inside, joined at every plate and floor as the house goes up. We test before drywall, while every seal is still easy to reach, and again when the house is done.

Target1.5 air changes per hour or lessTestedTwice: before drywall and when finished

FAQ

Common questions

What is a blower door test?

A tester mounts a powerful fan in an exterior door and pulls air out of the house. The fan measures how much air leaks back in through gaps, as a number called ACH50: how many times the air in the house would be replaced in an hour at the test pressure. Lower is tighter.

Is a blower door test required in Washington?

Yes. Washington's energy code requires every new home to be tested, and to leak no more than 5 air changes per hour at test pressure. Our Better and Best packages aim much lower: under half and under a third of that limit.

Can a house be too airtight?

Not if it has planned ventilation. Drafts aren't fresh air; they're cold air pulled through the walls and insulation. A tight house controls where air comes in, so we pair it with fresh-air ventilation: a heat-recovery ventilator (HRV) on Better and Best, and code-required ventilation on Good.